Digital-alert-systems DASDEC-II MANUAL Instrukcja Użytkownika Strona 104

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 171
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 103
98 Digital Alert Systems: DASDEC User Manual
4.10.3.1 Quick Connect to IPAWS CAP Server
To quick connect to the FEMA CAP Server, create a new client and follow the options in the screen
shot below.
Setup > Net Alerts > CAP Decode; Quick connect to FEMA CAP Server
Choose the IPAWS Open 2.0
Get Poll Protocol
Ensure that DNS is enabled (Setup >
Network > Configuration)
Type apps.fema.go
v
for the CAP server host
address and
IPAWSOPEN_EAS_SERVICE/rest/update
for the URL path
Enter your county and your state in your
FIPS list (And maybe some surrounding
counties)
(Last) When this says Connected you
are ready to decode CAP Alerts (You
may need to refresh the page)
Przeglądanie stron 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 170 171

Komentarze do niniejszej Instrukcji

Brak uwag